Analogue Multimeters

You are viewing 1 - 20 of 26 results
Display:
Results per page
20
  • 20
  • 50
  • 100
Price
(Price shown excludes VAT)
Part Details Brand Safety Category Calibrated Maximum Current Measurement Best AC Current Accuracy Best DC Current Accuracy Maximum Voltage Measurement Best AC Voltage Accuracy Best DC Voltage Accuracy Maximum Resistance Measurement Best Resistance Measurement Accuracy Battery Type Model Number p Length Height Dimensions Width Weight Safety Category Voltage Maximum Operating Temperature Battery Life Safety Category Level Minimum Operating Temperature
Kyoritsu 1110 Analogue Multimeter 300mA DC 600V ac/dc Kyoritsu CAT II 600 V, CAT III 300 V - 300mA dc - ±3 % 600V ac/dc ±4 % ±3 % 300 kΩ ±3 % AA x 2 1110 140mm 39mm 140 x 94 x 39mm 94mm 280g 300 V, 600 V - - CAT II, CAT III -
Gossen Metrawatt METRAHit 1A Analogue Multimeter 5000mA ac 500V Gossen Metrawatt CAT II 500 V - 5000mA ac - - 500V - - 1 MΩ - AA METRAHit 1A 92mm 45mm 92 x 126 x 45mm 126mm 0.3kg 500V +65°C - CAT II -25°C
Chauvin Arnoux C.A 5001 Analogue Multimeter 5A ac/dc 1000V ac/dc Chauvin Arnoux CAT III 600 V - 5A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % AA C.A 5001 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 15-Second Tests CAT III -10°C
Metrix MX 1 Analogue Multimeter 200A ac 1.5kV Metrix CAT III 600 V - 200A ac - - 1.5kV ±2.5 % ±2 % 20 kΩ ±10 % AA MX 1 40mm 150mm 40 x 98 x 150mm 98mm 420g 600V +50°C - CAT III -10°C
Metrix MX 2B Analogue Multimeter 10 A dc, 200 A ac 1.5kV ac/dc Metrix CAT III 600 V - 10 A dc, 200 A ac ±3 % ±2 % 1.5kV ac/dc ±2.5 % ±2 % 20 kΩ ±2.5 % AA MX 2B 150mm 40mm 150 x 98 x 40mm 98mm 420g 600V +50°C - CAT III -10°C
Chauvin Arnoux C.A 5001 Analogue Multimeter 5A ac/dc 1000V ac/dc, With RS Calibration Chauvin Arnoux CAT III 600 V RSCAL 5A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % AA C.A 5001 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 15-Second Tests CAT III -10°C
Chauvin Arnoux C.A 5001 Analogue Multimeter 5A ac/dc 1000V ac/dc, With UKAS Calibration Chauvin Arnoux CAT III 600 V UKAS 5A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % AA C.A 5001 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 15-Second Tests CAT III -10°C
Chauvin Arnoux C.A 5001 Analogue Multimeter with case 5A ac/dc 1000V ac/dc Chauvin Arnoux CAT III 600 V - 5A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % AA C.A 5001 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 15-Second Tests CAT III -10°C
Chauvin Arnoux C.A 5001 Analogue Multimeter with case 5A ac/dc 1000V ac/dc, With RS Calibration Chauvin Arnoux CAT III 600 V RSCAL 5A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % AA C.A 5001 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 15-Second Tests CAT III -10°C
Chauvin Arnoux C.A 5001 Analogue Multimeter with case 5A ac/dc 1000V ac/dc, With UKAS Calibration Chauvin Arnoux CAT III 600 V UKAS 5A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % AA C.A 5001 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 15-Second Tests CAT III -10°C
Chauvin Arnoux C.A 5005 Analogue Multimeter 300A ac/dc 1000V ac/dc Chauvin Arnoux CAT III 600 V - 300A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % 9V C.A 5005 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 10-second Tests CAT III -10°C
Chauvin Arnoux C.A 5005 Analogue Multimeter 300A ac/dc 1000V ac/dc Chauvin Arnoux CAT III 600 V - 300A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % 9V C.A 5005 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 10-second Tests CAT III -10°C
Chauvin Arnoux C.A 5005 Analogue Multimeter 300A ac/dc 1000V ac/dc, With RS Calibration Chauvin Arnoux CAT III 600 V RSCAL 300A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % 9V C.A 5005 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 10-second Tests CAT III -10°C
Chauvin Arnoux C.A 5005 Analogue Multimeter 300A ac/dc 1000V ac/dc, With UKAS Calibration Chauvin Arnoux CAT III 600 V UKAS 300A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±1.5 % 1 MΩ ±10 % 9V C.A 5005 160mm 56mm 160 x 105 x 56mm 105mm 500g 600V +55°C 10000 10-second Tests CAT III -10°C
Chauvin Arnoux C.A 5011 Analogue Multimeter 10A ac/dc 1000V ac/dc Chauvin Arnoux CAT III 1000 V - 10A ac/dc ±2.5 % ±2.5 % 1000V ac/dc ±2.5 % ±2.5 % 40 MΩ ±2.5 % 9V C.A 5011 160mm 56mm 160 x 105 x 56mm 105mm 500g 1000V +55°C 300 h CAT III -10°C
Gossen Metrawatt METRAHit 2A Analogue Multimeter 15A 500V Gossen Metrawatt CAT II 500 V - 15A - - 500V ±2 % ±2 % 1 MΩ - AA METRAHit 2A 92mm 45mm 92 x 126 x 45mm 126mm 0.3kg 500V +65°C - CAT II -25°C
Gossen Metrawatt METRAMAX 12 Digital Multimeter 10A 600V Gossen Metrawatt CAT II 600 V, CAT III 300 V - 10A ±2% + 5 Digits ±1.5% + 5 Digits 600V ±1% + 10 Digits ±0.5% + 2 Digits 40 MΩ ±2% + 5 Digits AA x 2 METRAmax 12 25mm 154mm 25 x 92 x 154mm 92mm 0.2kg 300 V, 600 V +30°C 300 h CAT II, CAT III -10°C
Gossen Metrawatt METRAmax 2 Analogue Multimeter 3A ac/dc 300V Gossen Metrawatt CAT III 300 V - 3A ac/dc - - 300V - - 10 MΩ - 9V METRAmax 2 100mm 35mm 100 x 140 x 35mm 140mm 0.3kg 300V +65°C 45 min CAT III -25°C
Gossen Metrawatt METRAport 3A Analogue Multimeter 10A 600V Gossen Metrawatt CAT II 600 V, CAT III 300 V - 10A - - 600V - - 20 MΩ - 9V METRAport 3A 146mm 44mm 146 x 118 x 44mm 118mm 0.45kg 300 V, 600 V +40°C - CAT II, CAT III 0°C
Kyoritsu 1110 Analogue Multimeter 300mA DC 600V ac/dc, With RS Calibration Kyoritsu CAT II 600 V, CAT III 300 V RSCAL 300mA dc - ±3 % 600V ac/dc ±4 % ±3 % 300 kΩ ±3 % AA x 2 1110 140mm 39mm 140 x 94 x 39mm 94mm 280g 300 V, 600 V - - CAT II, CAT III -
Check Our Stock Volumes
Enter the quantity you require and click 'Check'. Stock information was updated at
. This information is updated daily so availability may vary at time of order placement.
RS Stock No:
I'm Looking For 
Compare list full
You can only compare 8 products at a time

View or remove your products on your Compare page
You are viewing 1 - 20 of 26 results