Electrical Installation Testers

You are viewing 1 - 20 of 110 results
Display:
Results per page
20
  • 20
  • 50
  • 100
Price
(Price shown excludes VAT)
Part Details Brand Loop Impedance Test Type Calibrated Recently Introduced Insulation Test Voltage Maximum Voltage Measurement Test Type Interface Type Continuity Test Current RCD Test Type Test Standards Model Number p Dimensions Length Width Weight Height Battery Type Safety Category Maximum Continuity Resistance Minimum Continuity Resistance IP Rating Safety Category Voltage Display Type Plug Type Safety Category Level Minimum Operating Temperature Power Source Maximum Operating Temperature
Fluke 1664 FC Multifunction Tester with 115 Digital Multimeter Fluke Phase to Earth, Phase to Neutral - - 50 V, 100 V, 250 V, 500 V, 1000 V 1000V - BLE, USB 10mA A/F, AC, B/B+, G, S - - 125 x 100 x 250mm 125mm 100mm 1.3 (with Battery)kg 250mm 1.2 V NiMH, AA Alkaline IEC LR6 CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V LCD - CAT III, CAT IV -10°C Battery +40°C
Fluke1664FC DE with FreeSW&3Day Seminar
  • RS Stock No. 144-6617
  • Brand Fluke
  • Mfr. Part No. 1664 DE- 3DAY SEM
Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 1000V - BLE, USB 10mA A/F, AC, B/B+, G, S - 1664 FC 125 x 100 x 250mm 125mm 100mm 1.3 (with Battery)kg 250mm 1.2 V NiMH, AA Alkaline IEC LR6 CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V LCD - CAT III, CAT IV -10°C Battery +40°C
Fluke1664FC DE with FreeSW&OnlineSeminar
  • RS Stock No. 144-6618
  • Brand Fluke
  • Mfr. Part No. 1664 DE- 3HR SEM
Fluke Phase to Earth, Phase to Neutral - 50 V, 100 V, 250 V, 500 V, 1000 V 1000V - BLE, USB 10mA A/F, AC, B/B+, G, S - 1664 FC 125 x 100 x 250mm 125mm 100mm 1.3 (with Battery)kg 250mm 1.2 V NiMH, AA Alkaline IEC LR6 CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V LCD - CAT III, CAT IV -10°C Battery +40°C
Gossen Metrawatt M520P Electrical Tester Gossen Metrawatt Line to Earth - 1000V 500V Auto Test, RCD Test, RCD Trip Current, RCD Trip Time Bluetooth - B, B+, G, R IEC 60364-6, IEC 61851, IEC/EN 61010-1, IEC/EN 61557 M520P 260 x 330 x 90mm 260mm 330mm 2.3kg 90mm 1.5 V AA CAT III 500 V, CAT IV 300 V <50kΩ - IP40 300 V, 500 V - - CAT III, CAT IV -5°C Battery +50°C
Gossen Metrawatt M520P Electrical Tester Gossen Metrawatt Line to Earth - 1000V 500V Auto Test, RCD Test, RCD Trip Current, RCD Trip Time Bluetooth - B, B+, G, R IEC 60364-6, IEC 61851, IEC/EN 61010-1, IEC/EN 61557 M520P 260 x 330 x 90mm 260mm 330mm 2.3kg 90mm 1.5 V AA CAT III 500 V, CAT IV 300 V <50kΩ - IP40 300 V, 500 V - - CAT III, CAT IV -5°C Battery +50°C
Gossen Metrawatt M520P Electrical Tester Gossen Metrawatt Line to Earth - 1000V 500V Auto Test, RCD Test, RCD Trip Current, RCD Trip Time Bluetooth - B, B+, G, R IEC 60364-6, IEC 61851, IEC/EN 61010-1, IEC/EN 61557 M520P 260 x 330 x 90mm 260mm 330mm 2.3kg 90mm 1.5 V AA CAT III 500 V, CAT IV 300 V <50kΩ - IP40 300 V, 500 V - - CAT III, CAT IV -5°C Battery +50°C
MFT1711-BS Installation Tester UK Ver. Megger 2 Wire, 3 Wire - - 250 V, 500 V, 1000 V 600V Continuity Wireless 200mA A, AC, S EC 61010-1:2010, IEC 61010-031:2008, IEC 61010-30:2010, IEC 61557:2007 MFT1711 85 x 235 x 150mm 85mm 235mm 1 (with Battery; Excluding Case)kg 150mm AA Alkaline CAT III 600 V, CAT IV 300 V 99.9kΩ 0.01Ω IP54 300 V, 600 V LCD BS 1363, LT 300-EN-BS CAT III, CAT IV -10°C Battery +55°C
17th Edition Installation Test Kit ISO-TECH - - - - - Continuity, Insulation - - - - IEK3100 - - - - - AA CAT III 300 V - - - 300V LCD - CAT III 0°C Battery +40°C
MFT1731 Onsite Inst. Tester and Software Megger 2 Wire, 3 Wire - - 100 V, 250 V, 500 V, 1000 V 600V Continuity Wireless 200mA A, AC, B, S EC 61010-1:2010, IEC 61010-031:2008, IEC 61010-30:2010, IEC 61557:2007 MFT1731 On Site 390 x 285 x 220mm 390mm 285mm 1 (with Battery; Excluding Case)kg 220mm 1.2 V NiMH CAT III 600 V, CAT IV 300 V 99.9kΩ 0.01Ω IP54 300 V, 600 V LCD BS 1363, LT 300-EN-BS CAT III, CAT IV -10°C Battery +55°C
1662 Installation Tester UK Version Fluke Phase to Earth, Phase to Neutral - - 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity - 10mA - - 1662 100 x 250 x 125mm 100mm 250mm 1.3 (with Battery)kg 125mm AA CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V - UK CAT III, CAT IV - Battery -
1663 Installation Tester UK Version Fluke Phase to Earth, Phase to Neutral - - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity USB 10mA A/F, AC, B/B+, G, S - 1663 100 x 250 x 125mm 100mm 250mm 1.3 (with Battery)kg 125mm AA CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V - UK CAT III, CAT IV - Battery -
Kewtech Corporation KT63 Electrical Tester Kewtech Corporation 3 Wire - - 1000V dc 250V Continuity - 200mA AC Type BS 7671 KT63 - - - - - - - 1999Ω 9.99Ω IP54 - - - - - Battery -
MFT1731-BS Installation Tester UK Ver. Megger 2 Wire, 3 Wire - - 100 V, 250 V, 500 V, 1000 V 600V Continuity Wireless 200mA A, AC, B, S EC 61010-1:2010, IEC 61010-031:2008, IEC 61010-30:2010, IEC 61557:2007 MFT1731 390 x 285 x 220mm 390mm 285mm 1 (with Battery; Excluding Case)kg 220mm 1.2 V NiMH CAT III 600 V, CAT IV 300 V 99.9kΩ 0.01Ω IP54 300 V, 600 V LCD BS 1363, LT 300-EN-BS CAT III, CAT IV -10°C Battery +55°C
1664 FC Installation Tester UK Version Fluke Phase to Earth, Phase to Neutral - - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity BLE, USB 10mA A/F, AC, B/B+, G, S - 1664FC 100 x 250 x 125mm 100mm 250mm 1.3 (with Battery)kg 125mm AA CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V - UK CAT III, CAT IV - Battery -
Kewtech Corporation KT65DL Electrical Tester Kewtech Corporation 2 Wire, 3 Wire - - 100V 500V Continuity USB 200mA AC Type EN 61557, IEC 61557 KT65DL 235 x 136 x 114mm 235mm 136mm 1.4kg 114mm AA, LR6 CAT III 300 V 2000Ω 20Ω IP40 300V Backlight - CAT III 0°C Battery +40°C
MFT1721-BS Installation Tester UK Ver. Megger 2 Wire, 3 Wire - - 100 V, 250 V, 500 V, 1000 V 600V Continuity Wireless 200mA A, AC, B, S EC 61010-1:2010, IEC 61010-031:2008, IEC 61010-30:2010, IEC 61557:2007 MFT1721 85 x 235 x 150mm 85mm 235mm 1 (with Battery; Excluding Case)kg 150mm AA Alkaline CAT III 600 V, CAT IV 300 V 99.9kΩ 0.01Ω IP54 300 V, 600 V LCD BS 1363, LT 300-EN-BS CAT III, CAT IV -10°C Battery +55°C
1664 FC tester and DMS Software UK Ver.
  • RS Stock No. 113-5132
  • Brand Fluke
  • Mfr. Part No. FLK-1664FC DMS UK
Fluke Phase to Earth, Phase to Neutral - - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity BLE, USB 10mA A/F, AC, B/B+, G, S - 1664FC 100 x 250 x 125mm 100mm 250mm 1.3 (with Battery)kg 125mm AA CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V - UK CAT III, CAT IV - Battery -
Fluke 1664 UK with T150 and DMS Software
  • RS Stock No. 130-9780
  • Brand Fluke
  • Mfr. Part No. 1664 UK-TPL KIT
Fluke Phase to Earth, Phase to Neutral - - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity UK Mains 10mA A, AC, B, B+, F, G, S - 1664 100 x 250 x 125mm 100mm 250mm 1.3 (with Battery)kg 125mm AA CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V LCD UK CAT III, CAT IV -10°C Battery +40°C
Fluke 1663 UK with T130 and DMS Software
  • RS Stock No. 130-9779
  • Brand Fluke
  • Mfr. Part No. 1663 UK-TPL KIT
Fluke Phase to Earth, Phase to Neutral - - 50 V, 100 V, 250 V, 500 V, 1000 V 500V ac/dc Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity UK Mains 10mA A, AC, B, B+, F, G, S - 1663 100 x 250 x 125mm 100mm 250mm 1.3 (with Battery)kg 125mm AA CAT III 500 V, CAT IV 300 V 2000Ω 20Ω IP40 300 V, 500 V LCD UK CAT III, CAT IV -10°C Battery +40°C
+RS Cal (6679655) PowerPlus 1557 Tester Seaward - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Check Our Stock Volumes
Enter the quantity you require and click 'Check'. Stock information was updated at
. This information is updated daily so availability may vary at time of order placement.
RS Stock No:
I'm Looking For 
Compare list full
You can only compare 8 products at a time

View or remove your products on your Compare page
You are viewing 1 - 20 of 110 results