Technical documents
Specifications
Brand
JumoOutput Type
Relay
Supply Voltage
230 V ac
Size
170 x 108mm
Number of Inputs
Analogue
Number of Outputs
3
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+55°C
Control Type
PID Controller
Display Type
LED
IP Rating
IP50
Range
dTRON 316 (Lab Controller)
Series
dTRON
Additional Functionality
ON/OFF, PID
Input Type
Universal
Termination Type
Screw
Panel Depth
200mm
Display Colour
Red/Green
Country of Origin
Germany
Product details
LR 316.1 - Compact Laboratory Controllers in Plastic Bench Case
For controlling the temperature of heating plates, heating coils, tempering baths and heating furnaces in laboratories and production
Operation, parameterisation and configuration via four keys on the spray-protected front panel
Self-optimisation
Ramp function
Programme function with four programme sections
Digital input filter with programmable filter time constant
Keyboard and level locking
2 set-points with set-point switching
2 parameter sets with parameter set switching
Binary input functions
Keyboard locking
Level locking
Programme/ramp stop
Programme/ramp start
Set-point value switching
Parameter set switching
Enabling of limit comparators
Accessories supplied
1 plug for transducer, 6-pole
1 plug for control input/output, 4-pole
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical documents
Specifications
Brand
JumoOutput Type
Relay
Supply Voltage
230 V ac
Size
170 x 108mm
Number of Inputs
Analogue
Number of Outputs
3
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+55°C
Control Type
PID Controller
Display Type
LED
IP Rating
IP50
Range
dTRON 316 (Lab Controller)
Series
dTRON
Additional Functionality
ON/OFF, PID
Input Type
Universal
Termination Type
Screw
Panel Depth
200mm
Display Colour
Red/Green
Country of Origin
Germany
Product details
LR 316.1 - Compact Laboratory Controllers in Plastic Bench Case
For controlling the temperature of heating plates, heating coils, tempering baths and heating furnaces in laboratories and production
Operation, parameterisation and configuration via four keys on the spray-protected front panel
Self-optimisation
Ramp function
Programme function with four programme sections
Digital input filter with programmable filter time constant
Keyboard and level locking
2 set-points with set-point switching
2 parameter sets with parameter set switching
Binary input functions
Keyboard locking
Level locking
Programme/ramp stop
Programme/ramp start
Set-point value switching
Parameter set switching
Enabling of limit comparators
Accessories supplied
1 plug for transducer, 6-pole
1 plug for control input/output, 4-pole