Technical documents
Specifications
Brand
SickSupply Voltage
24V dc
Number of Channels
1, 2
Safety Contacts
3
Function
Speed/Standstill Monitoring
Terminal Type
Screw
Series
UE12
Width
17.8mm
Safety Category
4
Depth
70.8mm
Performance Level
e
Length
89.8mm
Country of Origin
Germany
Product details
UE10 and UE12, Dual Channel
Safety relay suitable for use with safety laser scanners and safety light curtains. The UE12-2FG2DO (stock number 701-9216) can have the number of outputs increased with the cascading jumper that is supplied with it
NC contact for external device monitoring (EDM)
2 LEDs
Maximum power consumption DC: 3.2 W
Rated operating current (voltage): 3 A (230Vac), 4 A (24Vdc)
Maximum switching current: 6 A
B10d parameter: 400000
TM (Mission Time): 20 a
SIL3 (IEC 61508), SILCL3 (IEC 62061), Category 4 (EN 954-1), same as protective device, PL e (EN ISO 13849)
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical documents
Specifications
Brand
SickSupply Voltage
24V dc
Number of Channels
1, 2
Safety Contacts
3
Function
Speed/Standstill Monitoring
Terminal Type
Screw
Series
UE12
Width
17.8mm
Safety Category
4
Depth
70.8mm
Performance Level
e
Length
89.8mm
Country of Origin
Germany
Product details
UE10 and UE12, Dual Channel
Safety relay suitable for use with safety laser scanners and safety light curtains. The UE12-2FG2DO (stock number 701-9216) can have the number of outputs increased with the cascading jumper that is supplied with it
NC contact for external device monitoring (EDM)
2 LEDs
Maximum power consumption DC: 3.2 W
Rated operating current (voltage): 3 A (230Vac), 4 A (24Vdc)
Maximum switching current: 6 A
B10d parameter: 400000
TM (Mission Time): 20 a
SIL3 (IEC 61508), SILCL3 (IEC 62061), Category 4 (EN 954-1), same as protective device, PL e (EN ISO 13849)