Technical documents
Specifications
Brand
Phoenix ContactModule Type
Voltage Transducer
Input Signal Type
Voltage
Output Signal Type
Current, Voltage
Input Range
0 → 370V ac
Output Range
0 → 10 V, 0 → 20mA
Supply Voltage
18.5 → 30.2V dc
Mounting Type
DIN Rail Mount
Operating Temperature Range
-25 → +60°C
Series
MCR-VAC
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Country of Origin
Germany
Product details
Voltage Transducer for AC Voltages, MCR-VAC-UI-0-DC
Phoenix contacts 2811103 is a measuring transducer for voltage. This module can measure altering current voltages from 0 – 20 V AC and 0 – 440 V AC. This device has fully adjustable voltage ranges and has bi-directional output signals. Not to mention, the 2811103 Is easily DIN rail mounted and designed for AC voltages between 0V to 20V AC and 0V to 660 V AC. Phoenix Contacts 2811103 also features an zero-span adjustment of ±20%.
The input and output on this device are electrically isolated from each other.
Features and benefits:
- Adjustable voltage range
- Bidirectional output signals
- Zero-span adjustment of ±20%.
- Tool-free parameterization of measured values
- Tech-in configuration of measured value range
- DIN rail mounted
- Terminal block connections
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical documents
Specifications
Brand
Phoenix ContactModule Type
Voltage Transducer
Input Signal Type
Voltage
Output Signal Type
Current, Voltage
Input Range
0 → 370V ac
Output Range
0 → 10 V, 0 → 20mA
Supply Voltage
18.5 → 30.2V dc
Mounting Type
DIN Rail Mount
Operating Temperature Range
-25 → +60°C
Series
MCR-VAC
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+60°C
Country of Origin
Germany
Product details
Voltage Transducer for AC Voltages, MCR-VAC-UI-0-DC
Phoenix contacts 2811103 is a measuring transducer for voltage. This module can measure altering current voltages from 0 – 20 V AC and 0 – 440 V AC. This device has fully adjustable voltage ranges and has bi-directional output signals. Not to mention, the 2811103 Is easily DIN rail mounted and designed for AC voltages between 0V to 20V AC and 0V to 660 V AC. Phoenix Contacts 2811103 also features an zero-span adjustment of ±20%.
The input and output on this device are electrically isolated from each other.
Features and benefits:
- Adjustable voltage range
- Bidirectional output signals
- Zero-span adjustment of ±20%.
- Tool-free parameterization of measured values
- Tech-in configuration of measured value range
- DIN rail mounted
- Terminal block connections