RS PRO Insulated Ring Terminal, M8 (5/16) Stud Size, 0.5mm² to 1.5mm² Wire Size, Red

RS Stock No.: 267-3587Brand: RS PROIMPA: 0
brand-logo
View all in Ring Terminals

Technical documents

Specifications

Insulation

Insulated

Insulation Material

Nylon

Maximum Wire Size AWG

16AWG

Minimum Wire Size AWG

22AWG

Thickness

0.75mm

Minimum Wire Size mm²

0.5mm²

Maximum Wire Size mm²

1.5mm²

Contact Material

Copper

Inner Ring Diameter

8.4mm

Stud Size

M8 (5/16)

Outer Ring Diameter

11.6mm

Colour

Red

Overall Length

27.8mm

Brand

RS Pro

Country of Origin

Taiwan, Province Of China

Product details

Sentron 5SY Series Miniature circuit breakers

Miniature circuit breakers from Siemens, offer the highest quality and reliability. The excellent technical properties of the devices mean you are always on the safe side. Apart from that you benefit from the innovative mounting options which enable quick and easy installation. The miniature circuit breakers from Siemens can be combined as required with a wide range of supplementary components e.g. control current switches, fault signal contacts, shunt releases, under voltage releases, remote operating mechanisms or with RCCB units to provide protection for persons and against fire.

Features and Benefits

Enclosure: IP20 equipment
Automatic cut-out, 1, 2, 3 and 4-pole
DIN rail assembly
For use in industry, and in the functional and residential construction sector
Supports fast and convenient removal from the assembly

Standards

IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCB’s).

Q: What is the differences in the Tripping Curves B, C, and D?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors

Standards

EN 60898, VDE 0641 part of 11, IEC 60898

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

P.O.A.

RS PRO Insulated Ring Terminal, M8 (5/16) Stud Size, 0.5mm² to 1.5mm² Wire Size, Red

P.O.A.

RS PRO Insulated Ring Terminal, M8 (5/16) Stud Size, 0.5mm² to 1.5mm² Wire Size, Red
Stock information temporarily unavailable.

Buy in bulk

quantityUnit price
100 - 900P.O.A.
1000 - 2400P.O.A.
2500 - 4900P.O.A.
5000 - 9900P.O.A.
10000+P.O.A.

Technical documents

Specifications

Insulation

Insulated

Insulation Material

Nylon

Maximum Wire Size AWG

16AWG

Minimum Wire Size AWG

22AWG

Thickness

0.75mm

Minimum Wire Size mm²

0.5mm²

Maximum Wire Size mm²

1.5mm²

Contact Material

Copper

Inner Ring Diameter

8.4mm

Stud Size

M8 (5/16)

Outer Ring Diameter

11.6mm

Colour

Red

Overall Length

27.8mm

Brand

RS Pro

Country of Origin

Taiwan, Province Of China

Product details

Sentron 5SY Series Miniature circuit breakers

Miniature circuit breakers from Siemens, offer the highest quality and reliability. The excellent technical properties of the devices mean you are always on the safe side. Apart from that you benefit from the innovative mounting options which enable quick and easy installation. The miniature circuit breakers from Siemens can be combined as required with a wide range of supplementary components e.g. control current switches, fault signal contacts, shunt releases, under voltage releases, remote operating mechanisms or with RCCB units to provide protection for persons and against fire.

Features and Benefits

Enclosure: IP20 equipment
Automatic cut-out, 1, 2, 3 and 4-pole
DIN rail assembly
For use in industry, and in the functional and residential construction sector
Supports fast and convenient removal from the assembly

Standards

IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCB’s).

Q: What is the differences in the Tripping Curves B, C, and D?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors

Standards

EN 60898, VDE 0641 part of 11, IEC 60898