Telemecanique Sensors Pressure Switch, 27psi Min, 130psi Max, Differential Reading

RS Stock No.: 752-2440Brand: Telemecanique SensorsManufacturers Part No.: 9012GBW2
brand-logo
View all in Pressure Sensors

Technical documents

Specifications

Pressure Reading Type

Differential

Minimum Pressure Reading

27psi

Maximum Pressure Reading

130psi

Accuracy

±0.1 → 1 %

Media Measured

Gas, Liquid Level

Process Connection

NPT 1/4

Electrical Connection

12" NPT

Maximum Current

10 A

Supply Voltage

600 V

Housing Material

Zinc Plated Steel

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+120°C

Product details

9012 GBW Diaphragm High Pressure Adjustable

The 9012G single stage pressure switches are control circuit rated devices. This series of switches can be used in pneumatic and hydraulic systems and on a variety of machine and process applications to protect the equipment. These pressure switches can be used to either control or monitor the system pressure.

Diaphragm actuated
Buna-N Nitrile diaphragm, zinc plated steel housing

P.O.A.

Telemecanique Sensors Pressure Switch, 27psi Min, 130psi Max, Differential Reading

P.O.A.

Telemecanique Sensors Pressure Switch, 27psi Min, 130psi Max, Differential Reading

Stock information temporarily unavailable.

Stock information temporarily unavailable.

Technical documents

Specifications

Pressure Reading Type

Differential

Minimum Pressure Reading

27psi

Maximum Pressure Reading

130psi

Accuracy

±0.1 → 1 %

Media Measured

Gas, Liquid Level

Process Connection

NPT 1/4

Electrical Connection

12" NPT

Maximum Current

10 A

Supply Voltage

600 V

Housing Material

Zinc Plated Steel

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+120°C

Product details

9012 GBW Diaphragm High Pressure Adjustable

The 9012G single stage pressure switches are control circuit rated devices. This series of switches can be used in pneumatic and hydraulic systems and on a variety of machine and process applications to protect the equipment. These pressure switches can be used to either control or monitor the system pressure.

Diaphragm actuated
Buna-N Nitrile diaphragm, zinc plated steel housing