Technical documents
Specifications
Brand
CrouzetMonitoring Application
Voltage
Electrical Phase
3
Voltage Sensing Range
183 → 528V ac
Contact Configuration
SPDT
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Time Delay
0.3 → 30s
Series
M3US
Maximum Operating Temperature
+50°C
Dimensions
69 x 17.5 x 92.6mm
Maximum Voltage Sensed
528V ac
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
17.5mm
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
183V ac
Product details
3-phase Voltage Control Relay - C-Lynx
3 phase voltage controllers which monitor:- Undervoltage, adjustable from -2% to -20% of Under voltage,- Overvoltage, adjustable from 2% to 20% of Under Voltage,- Presence of the neutral (H3USN only), Measurements are taken between Phases for the H3US - M3US and between Phases and Neutral for the H3USN, Faults are signalled via LED's, distinguishing the origin of the fault (one LED for the upper and lower threshold).
H3US and M3US relays control overvoltage between phases, and undervoltage between phases
The H3USN relay controls overvoltage between phases, undervoltage between phases, and loss of neutral
Multi-voltage Products
True RMS measurement
LED status indication
P.O.A.
1
P.O.A.
Stock information temporarily unavailable.
1
Stock information temporarily unavailable.
Technical documents
Specifications
Brand
CrouzetMonitoring Application
Voltage
Electrical Phase
3
Voltage Sensing Range
183 → 528V ac
Contact Configuration
SPDT
Voltage Sensitivity
Overvoltage, Undervoltage
Mounting Type
DIN Rail
Time Delay
0.3 → 30s
Series
M3US
Maximum Operating Temperature
+50°C
Dimensions
69 x 17.5 x 92.6mm
Maximum Voltage Sensed
528V ac
Operating Temperature Range
+50°C
Minimum Operating Temperature
-20°C
Width
17.5mm
Height
92.6mm
Length
69mm
Minimum Voltage Sensed
183V ac
Product details
3-phase Voltage Control Relay - C-Lynx
3 phase voltage controllers which monitor:- Undervoltage, adjustable from -2% to -20% of Under voltage,- Overvoltage, adjustable from 2% to 20% of Under Voltage,- Presence of the neutral (H3USN only), Measurements are taken between Phases for the H3US - M3US and between Phases and Neutral for the H3USN, Faults are signalled via LED's, distinguishing the origin of the fault (one LED for the upper and lower threshold).
H3US and M3US relays control overvoltage between phases, and undervoltage between phases
The H3USN relay controls overvoltage between phases, undervoltage between phases, and loss of neutral
Multi-voltage Products
True RMS measurement
LED status indication